December 10, 2020 by admin VMware 3v0-41.19 practice test Welcome to your VMware 3v0-41.19 practice test QUESTION 1 An architect is helping an organization design an NSX-T Data Center solution. This information was gathered during aworkshop:1.There are three LUNs In the storage array.2.There is no additional budget to purchase any more hardware.3.LUN 1 usage is 90% and is configured with a high-performance profile.4.LUN 2 usage is 75% and is configured with a high availability profile.5.LUN 3 usage is 60% and is configured with a balanced performance/availability profile.6.A highly available NSX Management cluster is required.7.ECMP routing is required.Which should the architect recommend for the organization\\’s NSX-T Datacenter environment? A. Place all three NSX Managers on LUN 2 for high availability. B. Place all three NSX Managers on LUN 1 to avoid latency. C. Spread the NSX Managers across LUN 2 and LUN 3. D. Spread the NSX Managers across the three LUNs. None QUESTION 2 An architect is helping an organization with the Logical Design of an NSX-T Data Center solution. This information wasgathered during the assessment: There must be a performance-based SLA for East-West traffic.Which two key performance features should the architect recommend? (Choose two.) A. Setup RSS to leverage multiple cores. B. Enable GENEVE-Offload. C. Configure N-VDS Enhanced Data Path. D. Install advanced Edge pNIC Features. E. Leverage DPDK drivers. QUESTION 3 Which type of design includes vendor models, hostnames, IP Addresses, port connections, logical unit number sizes, and number of CPUs? A. High-Level Design B. Physical Design C. Logical Design D. Conceptual Design None QUESTION 4 An architect is helping an organization with the Logical Design of an NSX-T Data Center solution. This information wasgathered during the Assessment Phase:1. Customer Is concerned with NSX Manager availability.2.3 cabinets/racks are available in the data center.3.No integration with 3rd party solution is required.4.There is no budget for physical equipment acquisition.5.The 3 cabinets/racks do not share the same L2 domain.Which three should the architect include in their design to address the customer\\’s concern with NSX Manageravailability? (Choose three.) A. Use another NSX Manger IP in case an appliance falls. B. Deploy 2 cold standby NSX Manager appliances in rack 2/3. C. Deploy an NSX Manager Appliance per rack and cluster them. D. Use a physical/internal load-balancer with the cluster. E. Use separate IP per NSX Manager appliance per rack. F. Deploy a single active NSX Manager appliance in rack 1. QUESTION 5 An architect is helping an organization with the Conceptual Design of an NSX-T Data Center solution. This informationwas gathered by the architect during the Discover Task of the Engagement Lifecycle:1.Existing hardware will be used In any design proposal.2.Network bandwidth cannot be expanded.Which concept of the Discover Task do these items belong to? A. requirement B. risk C. constraint D. assumption None QUESTION 6 An architect is helping an organization with the Logical Design of an NSX-T Data Center solution. During discussionsabout Centralized Services NAT running on Tier-1 or Tier-0 LR the customer made these requests:1.Services contain stateful services.2.Services should be in high availability mode.Which two should the architect include in their design? (Choose two.) A. An active/active model should be used. B. NAT should be applied on the uplink Interface. C. Mix stateful and stateless NAT rules on the same LR. D. The high availability mode supported is only Active-Standby. E. Use only DNAT rules in stateful NAT. QUESTION 7 Which is associated with the Discover Task of the Engagement Lifecycle? A. Create and document logical and virtual design. B. Gather and document requirements, assumptions, and constraints. C. Build, deploy, implement, and test the design. D. Measure performance against customer\\’s requirements. None QUESTION 8 What would an architect recommend to a customer that wants to extend management to an additional data centerthrough Layer 2, but does not want to add additional NSX-T licensing? A. Deploy a standalone Edge as the L2 VPN client. B. Deploy a standalone NSX Controller. C. Deploy a standalone NSX Manager. D. Deploy a standalone Edge as the IPSec VPN. None QUESTION 9 Which three must be taken into consideration when creating a Logical Design for a planned migration? (Choose three.) A. A transport node can attach single VLAN transport zones with single N-VDS. B. An N-VDS with the same name can be attached to both Overlay and VLAN transport zones. C. An N-VDS can attach to both an Overlay and a VLAN transport zone to an N-VDS having different name/s. D. An N-VDS can only attach to a single Overlay transport zone. E. An N-VDS can only attach to a single VLAN transport zone. F. An N-VDS can only attach to multiple VLAN transport nodes. QUESTION 10 An architect is helping an organization with the Logical Design of an NSX-T Data Center solution. This information wasgathered during the Assessment Phase:1.There Isn\\’t much budget available for a new off-shore site.2.The new site is decentralized and no communication with the main data center is required.3.The design will need to cater to availability, upgrades, and failure scenarios.Which three should the architect recommend In their design? (Choose three.) A. Collapse of the Management/Edge/Compute cluster. B. A Shared Edge/Management cluster and one for Compute. C. Separate the host’s physical NICs for VSS and N-VDS. D. Install a minimum of 4 ESXi hosts On the site. E. Make all pNICs part of N-VDS and VMKs will be migrated. F. Install a minimum of 6 ESXi hosts on the site. QUESTION 11 According to the Discover Task of the Engagement Lifecycle, which statement would be classified as a risk? A. To retain certification to provide financial services to end customers, PCI-DSS audits need to be passed. B. A merger and acquisition process was recently completed and new company on-boarding is not completed. C. Due to existing contracts and purchase agreements, the existing server hardware needs to be re-used. D. Enough power and cooling capacity is available in each rack in the data center. None QUESTION 12 Refer to the exhibits.An architect is helping an organization with the Conceptual Design of an NSX-T Data Center solution. The conceptual design includes these requirements, assumptions, constraints, and risks:1.Critical applications must run across sites without changing the IP addresses.2.Business continuity and disaster recovery (BCDR) plans will leverage a second site running vSphere.3.RTO/RPO must be reduced for the recovery of applications on the secondary site.4.IT Teams require automation tools for configuration.Which Conceptual Design would the architect recommend to the customer? A. Design Option 3 B. Design Option 1 C. Design Option 2 D. Design Option 4 None QUESTION 13 An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.1.This information was gathered during a workshop:2.Some workloads should be moved to a Cloud Provider.3.Extend network\\’s VLAN or VNI across sites on the same broadcast domain.4.Enable VM mobility use cases such as migration and disaster recovery without IP address changes.5.Support 1500 byte MTU between sites.Which should the architect include in their design? A. SSL VPN B. Reflexive NAT C. L2 VPN D. Load Balancer None Time's up